Link G4+ EMS Training Part 19: Open Loop Boost Control
Evans Performance Academy Lifetime Membership
•
52m
Link G4+ training part 19 walks you through how the open loop boost control works in the PCLink software. Several examples of open loop boost configuration are used from boost by gear, boost by ground speed, low/high boost and trim pot / multiple boost levels.
Up Next in Evans Performance Academy Lifetime Membership
-
Link G4+ EMS Training Part 18: Driven...
Link G4+ training part 18 walks you through setting up the driven vehicle speed sensor and gear ratio calculation.
-
Link G4+ EMS Training Part 17: Engine...
Link G4+ training part 17 walks you through how the engine protection features work, configuring a custom page layout and setting up the user defined fail safe protection for oil pressure and lean protection.
-
Link G4+ EMS Training Part 16: Idle C...
Link G4+ training part 16 walks you through how both the open and closed loop idle control works, and illustrates the programming differences between using a stepper idle motor or idle solenoid valve.